Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
J Pharm Bioallied Sci ; 16(Suppl 1): S168-S170, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595453

RESUMO

Introduction: To identify gender-based differences in pulpal sensory thresholds in human teeth utilizing various conducting media. Materials and Methods: The study involved 50 participants of both genders equally distributed. The maxillary central incisors were the teeth selected for the intervention. The three conducting media that were put to the test were Colgate Sensitive Pro-Relief Enamel Repair Toothpaste (CS), Himalaya herbals sensitivity toothpaste (HS), and Lignox 2% gel (LG). Subject's sensory threshold readings as well as the Visual analogue scale (VAS) scores were noted at the tiniest sensation they experienced. Following an ANOVA, a post hoc analysis was performed to confirm the significance between the three media. Results: Lox 2% Jelly significantly reduced sensory threshold values compared to the other conducting media (P < 0.001). Comparing the sensory threshold values of the sexes showed that men have greater values. Male and female readings differed significantly in the Lox 2% Jelly group (P = 0.021), whereas Colgate Sensitive Pro-Relief Enamel Repair Toothpaste, Himalaya herbals sensitivity toothpaste (P < 0.001) groups showed highly significant variances. All the three conducting media had a highly significant variance for the VAS scores. (P < 0.001). Conclusion: The conducting material used and gender affect the pulpal sensory thresholds to electric impulses produced by EPT.

2.
Clin Exp Dent Res ; 10(1): e817, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38345511

RESUMO

OBJECTIVE: This study assessed whether combining photobiomodulation therapy (PBMT) with casein phosphopeptide-amorphous calcium phosphate fluoride (CPP-ACPF) paste can effectively reduce post-home whitening tooth sensitivity (TS) without compromising shade change. METHODS: Fifty participants were selected and assigned to one of four groups: (1) PLACEBO group-received a placebo paste and PBMT simulation; (2) PBMT group-received a placebo paste + PBMT; (3) CPP-ACPF group-received CPP-ACPF paste and PBMT simulation; (4) CPP-ACPF + PBMT group-received both CPP-ACPF paste and PBMT. The participants used whitening trays containing 22% carbamide peroxide for 2 h a day for 21 days. TS was measured daily using a visual analog scale, while shade change was assessed using a spectrophotometer: before bleaching treatment (T0), after the first (T1), second (T2), and third (T3) weeks of treatment, and 30 days (T4) after completing the whitening treatment. RESULTS: Intragroup analysis revealed that the PLACEBO group had the highest increase in sensitivity during the whitening treatment. The CPP-ACPF and PBMT groups showed no significant difference tooth whitening (TW) between weeks regarding aesthetic change. The CPP-ACPF and PBMT group exhibited a significant reduction in TS between the first and third and between the second and third weeks TW, but not between the first and second. Conversely, the PLACEBO group showed a higher sensitivity than the other groups (p < .05). The CPP-ACPF and PBMT groups did not differ from each other. Furthermore, the CPP-ACPF and PBMT group showed a greater decrease in sensitivity than the PLACEBO group at T1, T2, and T3 (p < .01), and was significantly differed from CPP-ACPF and PBMT groups only at T2 and T3. All groups confirmed TW effectiveness. Student's and paired t-test did not reveal any significant difference between groups (p > .05). CONCLUSION: Therefore, PBMT associated with CPP-ACPF paste can reduce TS without compromising the efficacy of TW.


Assuntos
Fosfatos de Cálcio , Sensibilidade da Dentina , Terapia com Luz de Baixa Intensidade , Humanos , Fluoretos/uso terapêutico , Sensibilidade da Dentina/prevenção & controle , Caseínas/uso terapêutico , Fosfopeptídeos , Ensaios Clínicos Controlados Aleatórios como Assunto
3.
Artigo em Inglês | MEDLINE | ID: mdl-38373222

RESUMO

AIM: Insufficient evidence is available in quantifying the retention between the simplified and conventional non-balanced dentures. The aim of the study was to quantify, compare the maxillary denture retention and patient satisfaction between conventional and simplified removable non-balanced complete dentures. METHOD: The randomized clinical trial recruited 44 patients (n=22) with definitive criteria. Simplified and conventional non-balanced complete dentures were fabricated for the intervention groups. The denture retention of maxillary complete denture was assessed with dynamometer and patient satisfaction with visual analogue scale. The mean retention of maxillary denture and satisfaction were recorded at 0-,3-, and 6 - month interval. The data were statistically analyzed. (α=.05). RESULTS: The mean ±SD of retention for conventional denture at 0, 3, and 6 months by dynamometer ranged from 121.73 ± 1.64 N to 120.55 ± 1.57 N and 110.77 ±1.45N to 109.59±1.97 N for simplified denture. The mean ±SD of visual analogue score varied between 9.45±0.35 to 7.19± 0.69 for conventional dentures and 8.00 ±1.39 to 6.81±0.82 for simplified dentures. The repeated ANOVA, t-test and post-hoc Bonferroni revealed statistically significant differences between the two types of denture. (P⟨.05) Conclusion: Numerical retention and satisfaction were higher in conventional non-balanced denture than simplified denture.

4.
J Am Dent Assoc ; 155(4): 304-311, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38244017

RESUMO

BACKGROUND: The authors evaluated the synergistic analgesic effect of preemptive administration of 400 mg of ibuprofen (IBU) and potassium fluoride 2% (KF2), both in isolation or combination, on the painful perception of tooth sensitivity after tooth bleaching. METHODS: Fifteen patients participated in this triple-blind, randomized, placebo-controlled clinical trial. The study used a crossover design for drug administration and a split-mouth design for desensitizer agent. Four paired groups were formed: IBU plus KF2 (IBU + KF2); IBU (IBU + placebo KF); KF2 (placebo IBU + KF2), and placebo (placebo IBU + placebo KF). The outcome measure was the perception of tooth sensitivity, assessed using a visual analog scale. Data were collected at 4 different times: immediately after tooth bleaching (baseline) and after 6, 30, and 54 hours. Statistical analysis was performed using the Friedman test and relative risk. RESULTS: IBU plus KF2 was found to be more effective in reducing tooth sensitivity immediately after bleaching (baseline) compared with the placebo group (P < .05). The risk of experiencing moderate or severe tooth sensitivity was approximately 4 times higher in the placebo group than in the IBU plus KF2 group (relative risk, 4.00; 95% CI, 1.01 to 15.81; P = .025). CONCLUSIONS: The combined use of 400 mg of IBU and KF2 appears to be beneficial in managing postbleaching tooth sensitivity. It provides a superior analgesic effect compared with placebo. PRACTICAL IMPLICATIONS: The preemptive administration of IBU plus KF2 reduces tooth sensitivity after tooth whitening when compared with placebo. This clinical trial was registered in the Brazilian Clinical Trials Registry Platform. The registration number is U1111-1249-8191.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Humanos , Ibuprofeno/efeitos adversos , Sensibilidade da Dentina/etiologia , Sensibilidade da Dentina/prevenção & controle , Sensibilidade da Dentina/tratamento farmacológico , Peróxido de Hidrogênio , Clareamento Dental/efeitos adversos , Analgésicos , Método Duplo-Cego , Resultado do Tratamento
5.
Rev. Ciênc. Plur ; 9(3): 32620, 26 dez. 2023. tab, ilus, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1524464

RESUMO

Introdução:Sabe-se que a busca pela estética é algo cada vez mais crescente. Dentre os procedimentos mais procurados na odontologia estética, destaca-se o clareamento dental de consultório. Diante disso, ainda são poucos os estudos que avaliam os efeitos dos agentes clareadores de diferentes pHs na efetividade clareadora e na sensibilidade dentária.Objetivo:Avaliar a sensibilidade dentária e a eficácia clareadora de géis clareadores à base de peróxido de hidrogênio a 35% com diferentes pHs.Metodologia:Trata-se de um relato de três casos, descritivo e observacional, do tipo boca dividida (split-mouth) para cada estratégia clareadora (gel clareador com pH básico e gel clareador com pH ácido). Foram avaliados três pacientes de25, 26e 27anos de idade.Realizou-se registro de cor por meio da escala VITAClassical e avaliação da sensibilidade dentária pela escala visual analógica. Resultados:Todos os pacientes avaliados apresentaram cor A3 no registro de cor inicial e, após o clareamento dental,atingiram a cor A1. Todos relataram uma maior sensibilidade no hemiarco direito (local onde foi aplicada o gel clareador Whiteness HP que possui pH ácido. Dois pacientes relataram sensibilidade dentária no hemiarco esquerdo em que foi aplicado o gel clareador de pH básico. Conclusões:Observa-se a eficácia clínica dos géis clareadores de consultório à base de peróxido de hidrogênio a 35% na estabilidade de cor após o tratamento clareador, independente do seu pH. Ademais, nota-se que o gel clareador de pH básico promoveu menor sensibilidade pós-operatória (AU).


Introduction:It is known that the search for aesthetics is something increasingly growing. Among the most sought-after procedures in cosmetic dentistry, in-office tooth bleaching stands out. Therefore, there are still few studies that evaluate the effects of bleaching agents ofdifferent pHs on bleaching effectiveness and tooth sensitivity.Objective:To evaluate tooth sensitivity and bleaching efficacy of 35% hydrogen peroxide-based tooth bleaching gels with different pHs.Methodology:This is a report of three cases, descriptive and observational, of the split-mouth type for each bleaching strategy (bleaching gel with basic pH and bleaching gel with acidic pH). Three patients aged 25, 26 and 27 years were evaluated. Color registration was performed using the VITA Classical scale and tooth sensitivity was evaluated using the visual analogue scale.Results:All evaluated patients presented color A3 in the initial color registration and, after tooth bleaching, reached color A1. All reported greater sensitivity in the right hemi-arch (place where the Whiteness HP bleaching gel with an acid pH was applied. Two patients reported tooth sensitivity in the left hemi-arch where the basic pH bleaching gel was applied.Conclusions:The clinical efficacy of in-office tooth bleaching gels based on 35% hydrogen peroxide in terms of color stability after bleaching treatment is observed, regardless of its pH. In addition, it is noted that the basic pH bleaching gel promoted less postoperative sensitivity (AU).


Introducción: Se sabe que la búsqueda de la estética es algo cada vez más creciente. Entre los procedimientos más populares en odontología estética, se destaca el blanqueamiento dental en consultorio. Ante esto, aún existen pocos estudios que evalúen los efectos de agentes blanqueadores de diferentes pHs sobre la efectividad del blanqueamiento y la sensibilidad dental.Objetivo: Evaluar la sensibilidad dental y la eficacia blanqueadora de geles blanqueadores a base de peróxido de hidrógeno al 35 % con diferentes pH. Metodología: Este es un reporte de tres casos, descriptivo y observacional, del tipo boca partida para cada estrategia de blanqueamiento (gel blanqueador con pH básico y gel blanqueador con pH ácido). Se evaluaron tres pacientes de 25, 26 y 27 años. El registro de color se realizó con la escala clásica VITA y la sensibilidad dental se evaluó con la escala analógica visual.Resultados: Todos los pacientes evaluados presentaron color A3 en el registro de color inicial y, después del blanqueamiento dental, alcanzaron el color A1. Todos refirieron mayor sensibilidad en la hemiarcada derecha (lugar donde se aplicó el gel blanqueador de pH ácido Whiteness HP). Dos pacientes refirieron sensibilidad dental en la hemiarcadaizquierda donde se aplicó el gel blanqueador de pH básico.Conclusiones: Se observala eficacia clínica de los geles blanqueadores de consultorio a base de peróxido de hidrógeno al 35% en cuanto a la estabilidad del color tras el tratamiento blanqueador, independientemente de su pH. Además, se observa que el gel blanqueador de pH básico promovió una menor sensibilidad postoperatoria (AU).


Assuntos
Humanos , Adulto , Cor , Sensibilidade da Dentina/complicações , Clareadores Dentários/efeitos adversos , Peróxido de Hidrogênio , Resultado do Tratamento , Estudo Observacional , Concentração de Íons de Hidrogênio
6.
Int J Dent Hyg ; 2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37632216

RESUMO

OBJECTIVES: Even though tooth sensitivity is a prevalent dental issue today, more information is available to patients via social media concerning the subject. This study aimed to examine what patients may learn about tooth sensitivity from online videos on YouTube™ and evaluate the accuracy of the information given. METHODS: In this cross-sectional investigation, two experienced periodontologists used the keyword 'tooth sensitivity' to conduct an organized search into YouTube videos containing knowledge regarding dentin hypersensitivity. Videos' type, origin, number of days since upload, duration, number of views, likes and dislikes, and comments were all noted; the viewing rate and interaction index were calculated. Videos were graded based on their content. The DISCERN and Global Quality Scales were used to rate each video's level of quality and reliability. RESULTS: After the initial 260 videos were examined, 199 were kept for additional study. Healthcare professionals, hospitals, and colleges posted the great majority of the videos. There was a significant positive relationship between the number of views and Total Content scores of the videos, the viewing rate, comments, and likes (p < 0.05). Significant relationships were obtained between total discernment, video type, source of upload, and global quality variables, and Total Content scores (p < 0.05). CONCLUSIONS: When looking for information on dentin hypersensitivity, patients might find watchable, reliable, and helpful videos on YouTube™.

7.
Artigo em Inglês | MEDLINE | ID: mdl-37649825

RESUMO

Background: The purpose of this systematic review was to assess the clinical efficacy (sensitivity reduction) and safety (gum damage) of silver diamine fluoride (SDF) as a tooth desensitizer for adults. Methods: The search strategy was developed and adapted from 12 databases. Two independent reviewers selected the studies in consensus with a third reviewer. Randomized clinical trials with adult volunteers affected by dentin hypersensitivity (DH), and receiving treatment with SDF were included. Studies with volunteers testing tooth whitening products, using some type of desensitizer, or taking analgesic or anti-inflammatory medication were excluded. The risk of bias was assessed according to the RoB 2 tool, and confidence in cumulative evidence, according to GRADE. Results: Only 3 articles were included. The average pain assessed using the visual analog scale was lower in the SDF groups than in the short-term control groups (24h to 7 days) (P=0.0134 and P=0.0015) of the two studies. The third study evaluated a combination of SDF and a CO2 laser, compared to using only SDF, and found no statistical difference between the two (P=0.74). Inflammation and gingival staining were also evaluated in two of the three studies. No adverse effects were reported. All the included studies had a high risk of bias, and the certainty of the evidence was very low. Conclusion: SDF can be used as a safe and effective tooth desensitizer in adults, with good results, as was achieved in a short-term follow-up. However, more studies with longer evaluation periods are required.

8.
Dent J (Basel) ; 11(7)2023 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-37504242

RESUMO

INTRODUCTION: The present study aimed to investigate the effectiveness of low-level laser therapy (LLLT) use before in-office bleaching to prevent an increase in the risk and intensity of tooth sensitivity. METHODS: Thirty patients were selected. Before bleaching with 38% hydrogen peroxide, the participants were randomly divided into two groups of 15 subjects. Test group: the patients' teeth were subjected to a preliminary LLLT procedure by an 810 nm diode laser with 0.5 W for 30 s for an energy density of 15 J/cm2 and a group placebo. All patients were instructed to report their cold sensitivity experiences immediately, 1 h, 24 h, and 48 h after the end of bleaching via a VAS score. RESULTS: The results obtained show an increase in VAS values for both groups (290 and 490 vs. 224 and 234 of baseline time of test and placebo group, respectively); afterward, the VAS value seemingly decreases at 1 h after the end of bleaching, approaching the baseline VAS for the test group (274) in comparison to the placebo group. CONCLUSIONS: The use of preliminary diode LLLT could represent a valid possibility to reduce the occurrence of tooth sensitivity post-whitening and shorten recovery time in cases where tooth sensitivity occurs.

9.
Eur Arch Paediatr Dent ; 24(3): 313-319, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37199855

RESUMO

AIM: The objective of this study was to investigate whether dental hypersensitivity and dental fear were linked to the presence and severity of MIH. METHODS: For this cross-sectional study, 1830 students between the ages of 6 and 12 years were recruited from four randomly selected schools. The Children's Fear Survey Schedule-Dental Subscale questionnaire was used to assess dental anxiety and fear. The children's self-reported dental hypersensitivity resulting from MIH was evaluated using the Wong-Baker Facial Scale and the Visual Analog Scale (VAS). RESULTS: MIH was correlated with tooth hypersensitivity, particularly in severe cases. Dental fear was present in 17.4% of the children with MIH, but it was not associated with dental hypersensitivity, gender, or age. CONCLUSION: No association was found between dental fear and dental hypersensitivity in children with MIH.


Assuntos
Hipoplasia do Esmalte Dentário , Hipomineralização Molar , Humanos , Criança , Ansiedade ao Tratamento Odontológico , Hipoplasia do Esmalte Dentário/complicações , Estudos Transversais , Dente Molar , Incisivo , Medo , Prevalência
10.
J Esthet Restor Dent ; 35(6): 821-833, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36883730

RESUMO

OBJECTIVE: This controlled randomized clinical trial determined the whitening efficacy and the intensity and absolute risk of tooth sensitivity in dual whitening when prefilled at-home whitening trays were used between in-office whitening intervals. MATERIALS AND METHODS: An in-office whitening agent containing 35% hydrogen peroxide was used. A prefilled tray with a whitening agent containing 6% hydrogen peroxide was used for at-home whitening. Sixty-six subjects were randomly assigned to three groups. Group I: at-home whitening was performed 10 times between the in-office whitening treatments. Group II: at-home whitening was performed five times between the in-office whitening treatments. Group III: only in-office whitening was performed. The tooth color changes were evaluated using a spectrophotometer. A visual analog scale was used to express the pain intensity. RESULTS: All the groups showed increased ΔE*ab, ΔE00 , and ΔWID with increased whitening sessions. Group I at the 3rd whitening session showed significantly higher ΔE*ab, ΔE00 , and ΔWID than group III. Tooth sensitivity showed higher values up to 24 h after whitening. CONCLUSIONS: Although dual whitening with the prefilled tray and in-office whitening had higher whitening ability than in-office whitening alone, the intensity and absolute risk of tooth sensitivity was similar. CLINICAL RELEVANCE: The dual whitening might produce faster and stronger whitening effects than in-office whitening alone.


Assuntos
Clareadores , Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Humanos , Peróxido de Hidrogênio , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
11.
Materials (Basel) ; 15(15)2022 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-35897604

RESUMO

Recently, the development of dental materials has increased the availability of various hyperesthesia desensitizers. However, there are no studies on the duration of retreatment in terms of adherence rates. Thus, the adhesion rates of resin-based desensitizers were investigated. We used a conventional desensitizer and a recently developed desensitizer containing calcium salt of 4-methacryloxyethyl trimellitic acid (C-MET) and 10-methacryloyloxydecyl dihydrogen calcium phosphate (MDCP). These colored agents were applied to the surfaces of premolars and molars, and the area was measured from weekly oral photographs. Areas were statistically analyzed and mean values were calculated using 95% confidence intervals. A p-value of <0.05 was considered statistically significant. These rates were significantly higher on the buccal side of the maxilla and lower on the lingual side of the maxilla. In addition, the desensitizer containing C-MET and MDCP displayed significantly higher adhesion rates. It is suggested that this will require monthly follow-ups and reevaluation because both agents cause less than 10% adherence and there is almost no sealing effect after 4 weeks. In addition, the significantly higher adhesion rate of the desensitizer containing C-MET and MDCP indicated that the novel monomer contributed to the improvement in the adhesion ability.

12.
Lasers Med Sci ; 37(8): 3237-3247, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35829976

RESUMO

This study aims to evaluate the effect of diode laser- or LED-activated tooth bleaching on color change, tooth sensitivity(TS), temperature variation, and gingival irritation (GI) for 9 months. Thirty-five subjects having anterior teeth with a color of A2 or darker were enrolled in the study. In a split-mouth design, one side of each arch was activated by a diode laser (Epic X, Biolase), and the other side was activated by an LED (Radii Plus, SDI) in conjunction with a bleaching agent (35%, Whiteness HP). The color change was evaluated by subjective (VitaClassic/Vita3D Master Bleachguide) and objective (spectrophotometer, Vita Easyshade) methods for up to 9 months. TS and GI were assessed by visual analogue scale (VAS) and gingival index, respectively, at the same recall periods. During the bleaching, the temperature variation was also recorded using a thermocouple. Statistical analyses were performed (p < 0.05). In the color evaluation, no statistically significant difference was found between diode laser and LED (p > 0.05), except for the 6-month spectrophotometric assessment (ΔE00, ΔEab), where higher values were obtained with the laser (p < 0.05). The temperature difference and maximum temperature with diode were found to be significantly higher than LED (p < 0.05). Higher values were obtained with LED when the mean temperatures were compared (p < 0.05). There was no difference between the two activation methods in terms of TS and GI at any of the recalls (p > 0.05). The bleaching activated either with diode laser or LED performed similar clinical performance in terms of effective color change, tooth sensitivity, and gingival irritation with minimum temperature variations.


Assuntos
Clareadores , Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Seguimentos , Humanos , Peróxido de Hidrogênio , Lasers Semicondutores/uso terapêutico , Clareamento Dental/métodos , Resultado do Tratamento
13.
Cureus ; 14(2): e22318, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35371703

RESUMO

Tooth sensitivity (TS), a common discomfort manifests as hypersensitivity, sharp and rapid pain, or shock-like sensation in response to tactile, thermal, or chemical stimuli which others perceive as normal, affecting a significant percentage of the population. Tetrabenazine, a vesicular monoamine transport 2 receptor inhibitor acting on presynaptic neuronal endings, is commonly used in acute dystonia treatment. Two cases are reported here, where the patient, after consuming tetrabenazine (TBZ), was noted to have TS after a week of treatment. On stopping TBZ and substituting it with oral anticholinergic, the adverse symptom disappeared and did not recur again. No drugs are yet known to cause TS as an adverse drug reaction, and this is the first report of drug-induced TS cases.

14.
Clin Oral Investig ; 26(5): 3853-3864, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34997849

RESUMO

OBJECTIVES: The aim of this study was to evaluate the effect of a protocol of photobiomodulation (PBM) with light-emitting diodes (LED) on the clinical risk of bleaching-induced sensitivity. MATERIALS AND METHODS: Sixty-four volunteers were selected and randomly divided in two groups, placebo (PG) and LED (LG). The LG received PBM irradiation and tooth bleaching, while the PG received tooth bleaching and simulation of the irradiation. The occurrence of painful sensitivity was recorded during the dental bleaching; immediately after bleaching; and 24, 48, and 72 h after tooth bleaching. At the same measurement times, data were collected on the intensity of sensitivity (VAS and NRS scale) and teeth affected by bleaching-induced sensitivity. A questionnaire sought to measure how the painful sensitivity influenced basic daily activities. Tooth color measures were performed using subjective and objective methods. RESULTS: LED irradiation decreased the occurrence of sensitivity at all studied evaluation times as well as its intensity, with the exception of the 72-h data when both groups presented no difference. Teeth affected by bleaching-induced sensitivity were significantly greater in the PG. Color measurements presented no differences between the groups in the recently after and later measures. CONCLUSIONS: PBM with LED decreases sensitivity risk and sensibility intensity during and after office bleaching and causes no influence on the shade degree of whitening achieved. The decrease in tooth sensitivity provided more comfort and less suffering while drinking. CLINICAL RELEVANCE: LED irradiation is a promising intervention in the control of bleaching-induced sensitivity. TRIAL REGISTRATION: RBR-7hpfwj. Sensitivity intensity measured by the VAS scale (0-10) in the first whitening session (Graphic A) and second whitening session (Graphic B). Significance level set at ≤ 5%. *Mann-Whiteney U test. Columns followed by the same letter are significant different (ap < 0.001; bp < 0.001; cp < 0.001; dp =0.013; ep < 0.001; fp < 0.001; gp < 0.001; hp = 0.002).


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Sensibilidade da Dentina/induzido quimicamente , Humanos , Peróxido de Hidrogênio , Ácido Hipocloroso , Clareamento Dental/métodos , Resultado do Tratamento
15.
Clin Oral Investig ; 26(3): 2719-2732, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35083586

RESUMO

OBJECTIVES: The purpose of this study was to identify the prevalence and predisposing and etiologic factors of dentin hypersensitivity (DH), as well as the demographic characteristics of patients. MATERIALS AND METHODS: The 1210 patients were examined. The research was based on a two-step investigation: questionnaire and clinical examination. DH was evaluated by the response of the patient to tactile and air-blast stimuli. Loss of attachment and gingival recession of sensitive teeth was measured on the buccal and lingual surfaces. Also, the tooth wear of sensitive teeth was graded on the buccal and lingual surfaces. Comparisons of nonnormally distributed continuous variables were performed using the Mann-Whitney U test and Kruskal-Wallis one-way analysis of variance (ANOVA) and Dunn's post hoc test. Comparisons of categorical variables were performed using Pearson's chi-square, Fisher's exact chi-square, Yates's chi-square, and the Monte Carlo chi-square test. RESULTS: One hundred twenty-four patients reported DH, showing a prevalence for self-reported DH of 10.2%. Eight hundred forty teeth were diagnosed as having DH, giving a clinical diagnosis rate of DH of 29.4%. Females (76.8%), the 31-40 years age group (26%), housewives (36.8%), and high school education level (38%) had the highest prevalence of DH as demographic properties. A cold stimulus was the most common stimuli trigger for hypersensitivity (97.1%). Occasional pain (55.5%) showed the highest prevalence in terms of frequency of DH. A higher rate of DH was found with the use of medium brushes (47.4%) and brushing twice per day (59.4%) for 1-2 min (56.2%) with the circular method (33.8%) as oral hygiene habits. The buccal surface of the lower right central incisors (5.7%) had the highest prevalence. The most affected teeth by DH were incisors (38.4%). The buccal surfaces (86.3%) of teeth showed a higher high prevalence of DH compared with the lingual surface (52.7%), similar to gingival recession (40.9% vs. 15.7%) and loss of attachment (68.3% vs. 42.6%). CONCLUSIONS: Clinically diagnosed DH was more common than self-reported DH. Some factors related to patients such as sex (female), the 31-40 years age group, housewives, high school students, using medium brushes, brushing twice per day, and the circular brushing method were more likely to have a risk for DH. Also, buccal surfaces of teeth, gingival recession, and loss of attachment on the buccal surface of teeth should be considered as predisposing factors for DH. CLINICAL RELEVANCE: To control and prevent DH, clinicians should consider patients' demographics, predisposing factors, and etiologic factors.


Assuntos
Sensibilidade da Dentina , Retração Gengival , Atrito Dentário , Sensibilidade da Dentina/diagnóstico , Sensibilidade da Dentina/epidemiologia , Sensibilidade da Dentina/etiologia , Feminino , Retração Gengival/epidemiologia , Humanos , Prevalência , Escovação Dentária/efeitos adversos
16.
Saudi Dent J ; 34(1): 62-67, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35068900

RESUMO

BACKGROUND: Professional tooth whitening has gained popularity in the past several years. The most commonly active chemical agent used in bleaching is hydrogen peroxide (HP). HP is a low molecular weight unstable material that easily diffuses into the tooth structure, causing oxidative reactions with a consequent whitening effect. After bleaching, tooth sensitivity and gingival irritation are anticipated. AIM: This study aimed to compare the effectiveness of remineralization and/or diode laser therapies in reducing tooth sensitivity after bleaching. METHODOLOGY: Thirty-nine participants from Umm Al-Qura University, dental clinics, Makkah, SA. They were divided into three equal groups according to the desensitizing technique used. All participants were subjected to bleaching by 40% opalescence boost HP. Subsequently, 13 participants received 5% sodium fluoride varnish (5% NaF), 13 participants received low-level laser therapy (LLLT), and 13 participants received a combination of both desensitizing techniques. Each participant represented self-control, where tooth sensitivity was measured before and after bleaching. The cold test was used to measure tooth sensitivity before bleaching, immediately after bleaching and after application of the proposed desensitizing technique. Then, a visual analogue scale (VAS) was used for re-assessment. RESULTS: The desensitizing methods exhibited a notable reduction in tooth sensitivity post-bleaching with no significant difference among the following therapies (p = 0.544). CONCLUSION: All the employed desensitizing methods reduced post-bleaching sensitivity, with no significant differences among them. Thus, using one technique individually is enough for effort, time and cost savings.

17.
Lasers Med Sci ; 37(3): 2017-2024, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34778937

RESUMO

This randomized, controlled, and double-blinded clinical trial evaluated the clinical performance of dental bleaching performed with 6% hydrogen peroxide containing TiO2-N nanoparticles exposed to blue and violet activation lights. Forty volunteers, selected according to the inclusion and exclusion criteria, were randomly distributed into four experimental groups (n = 10): 35% hydrogen peroxide (PH35)-control; 6% hydrogen peroxide (PH6) containing TiO2-N nanoparticles without light activation; PH6 activated with a blue LED (PH6A); and PH6 activated with a violet LED (PH6V). The three bleaching sessions consisted of 3 consecutive 16-min applications of the bleaching agent described for each group. The groups receiving LED activation were exposed to light intermittently every 1 min, with a total exposure time of 8 min in each application. Efficacy was determined by the color variation in the upper central incisors and canines, using reflectance spectroscopy analysis performed by a calibrated evaluator (ICC = 0.83). Tooth sensitivity was characterized according to the presence and intensity (SI) self-recorded in specific forms. The group treated with PH6V was as effective as the control group (PH35), whereas the groups PH6A and PH6 showed lower efficacy. Regardless of the activation, all groups treated with 6% hydrogen peroxide were less likely to cause sensitivity compared to the control group (PH35). The use pf PH6 activated by LED violet resulted in an effective and safe clinical protocol for in-office dental bleaching.Trial registration number: RBR-8pbydg; registration date: 08/29/2017.


Assuntos
Sensibilidade da Dentina , Nanopartículas , Clareadores Dentários , Clareamento Dental , Sensibilidade da Dentina/tratamento farmacológico , Humanos , Peróxido de Hidrogênio , Nanopartículas/química , Clareamento Dental/métodos , Resultado do Tratamento
18.
Clin Oral Investig ; 26(3): 2555-2564, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34668065

RESUMO

OBJECTIVES: To evaluate if the topical application of Otosporin® before in-office bleaching with a 35% hydrogen peroxide (HP) gel reduces the risk and intensity of tooth sensitivity (TS), as well as the bleaching effectiveness. MATERIALS AND METHODS: Twenty participants were selected for this split mouth, triple-blind, multicenter randomized clinical trial. Before each bleaching session, the placebo was applied in the patient's hemi-arch and the other half received the Otosporin®, according to the randomization procedure. Both products were applied topically for 10 min. The 35% HP was applied in two sessions with a 1-week interval. The risk and intensity of TS were assessed using the Numerical Scale (NRS) and the Visual Analog Scale (VAS). The bleaching effectiveness were evaluated with the visual scales and with a digital spectrophotometer. The absolute risk of TS was compared by McNemar's test. To compare the intensity of TS, the Wilcoxon signed-rank test was used to evaluate the NRS, while the paired t test was used to evaluate VAS. Bleaching effectiveness (ΔSGUs and ΔEab, ΔE00, and ΔWID) was compared between groups using the paired t-test (α = 0.05). RESULTS: No significant difference at risk (p = 1.0) and intensity of TS (p > 0.59; VAS and p = 1.00 for NRS) was detected between groups. For both groups, a significant bleaching was observed after 30 days of evaluation (p < 0.39). CONCLUSIONS: The previous application of Otosporin® in the in-office bleaching did not reduce the risk and intensity of TS and did not affect the effectiveness of the bleaching. CLINICAL RELEVANCE: The application of Otosporin® before in-office bleaching with 35% HP was not able to reduce the risk and intensity of TS.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Combinação de Medicamentos , Humanos , Hidrocortisona , Peróxido de Hidrogênio , Boca , Neomicina , Polimixina B , Resultado do Tratamento
19.
Clin Oral Investig ; 26(3): 2527-2536, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34654942

RESUMO

OBJECTIVES: Although bleaching therapy is considered a dose-dependent treatment, the effect of the volume of product used is yet to be studied. This study thus aimed to evaluate the influence of bleaching gel volume on chromatic alteration and postoperative sensitivity. METHODOLOGY: Thirty patients were selected and allocated into three groups; the lower canines were analyzed according to the volume of gel used: GI-0.025 mL, GII-0.05 mL, and GIII-0.10 mL. Chromatic alteration analysis was performed using a portable digital spectrophotometer by calculating the ΔE, ΔE00, ΔL*, Δa*, and Δb* values and the whiteness index (WID). Spontaneous sensitivity was assessed using a questionnaire, and sensitivity was stimulated by thermo-sensory analysis. Analyses were conducted in five stages: baseline, after 1st, 2nd, and 3rd bleaching sessions, and 14 days after the end. Data were analyzed using the two-way ANOVA test with repeated measures and Tukey's post hoc test (p < 0.05). RESULTS: It was observed that ΔE, ΔE00, and ΔL* were similar between groups at the end of the bleaching therapy; and the values of Δa*, Δb*, and WID were higher in the GIII group. For sensitivity, it was found that the GI was the one with the lowest values; o GII intermediate values; while the GIII group presents the highest values of spontaneous and stimulated sensitivity. CONCLUSION: Gel volume influenced the response to bleaching and significantly influenced the spontaneous sensitivity and cold stimulus. CLINICAL RELEVANCE: The amount of bleaching gel used during therapy is key to both the response to color change and postoperative sensitivity.


Assuntos
Clareadores Dentários , Clareamento Dental , Cor , Humanos , Peróxido de Hidrogênio , Ácido Hipocloroso , Espectrofotometria , Clareadores Dentários/uso terapêutico
20.
Int J Dent Hyg ; 20(4): 650-657, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34018341

RESUMO

OBJECTIVES: This study aims to compare the use of different remineralization agents before in-office bleaching for decreasing bleaching induced sensitivity. METHODS: A total of 64 volunteers were randomly divided into four groups. Before undergoing in-office bleaching with 38% hydrogen peroxide gel (three applications of 15 min each, one session), clinicians applied a placebo gel (control group), casein phosphopeptide-amorphous calcium phosphate (CPP-ACP), neutral sodium fluoride gel (NSF) or nano-hydroxyapatite solution (n-HAP) on all buccal surfaces of teeth. The gel was left undisturbed for 4 min. The efficacy of tooth whitening was assessed by determining the colour change using SGU. Patients recorded their tooth sensitivities on the VAS scale. Kruskal-Wallis test followed by Mann-Whitney U test was used to compare changes in tooth colour and intensity of tooth sensitivity between groups. RESULTS: Overall, there was no significant difference in shade change between the groups. Control and CPP-ACP groups showed significantly higher rates of hypersensitivity than NSF and the n-HAP group (p < 0.05). CONCLUSIONS: The use of a remineralization agent (n-HAP/NSF) before in-office bleaching did not affect the bleaching efficacy but did reduce tooth sensitivity. The before bleaching treatment use of an n-HAP solution can be suitable for reducing bleaching born sensitivity as well as commonly used NSF remineralizing gel before in-office tooth bleaching can reduce tooth sensitivity, the most common side effect associated with this procedure.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Humanos , Sensibilidade da Dentina/induzido quimicamente , Sensibilidade da Dentina/prevenção & controle , Sensibilidade da Dentina/tratamento farmacológico , Clareadores Dentários/efeitos adversos , Caseínas/uso terapêutico , Peróxido de Hidrogênio/efeitos adversos , Fluoreto de Sódio , Fosfopeptídeos , Clareamento Dental/efeitos adversos , Clareamento Dental/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...